Short definition
“Why is my water pressure low” is one of the highest-volume diagnostic searches in residential plumbing. The honest answer: there’s a short list of common causes, and a $10 hose-bib pressure gauge plus a few simple checks tell you which one you have. This entry walks the diagnostic tree.
Diagnostic walkthrough
Three quick questions narrow the cause before you do anything else:
- One fixture or whole house? One fixture suggests a clogged aerator, a scaled showerhead, or a partially closed angle stop. Whole-house points to the supply.
- Hot only, cold only, or both? Hot-only points to the water heater (sediment, a partly closed isolation valve) or hot-side pipe scaling. Cold-only is rare — usually points to a shutoff. Both points to the supply or service line.
- Sudden or gradual? Sudden after a recent service call usually means a valve was left partially closed. Gradual over years suggests internal pipe restriction (tuberculation in galvanized) or a slowly clogging service line.
The static pressure test
Before going any further, run a static pressure test. Screw a hose-bib gauge onto any exterior hose bib, close everything else, open the bib, and read.
- 65 psi static, but fixtures feel weak. The supply is fine; the problem is downstream. Check aerators, showerheads, and angle stops.
- 35 psi static. Below the normal band. Could be a partially closed inside main shutoff, a partially closed curb stop (utility-side), a tuberculated old galvanized service line, a misadjusted PRV, or a genuine utility-side problem.
- 18 psi static. Way below normal — call the utility first to rule out a main-side issue, then look at a partial shutoff or major service-line restriction.
The short list of causes
- Clogged aerator or showerhead (single fixture). Unscrew, soak in vinegar overnight, reinstall.
- Partially closed shutoff valve (whole house, sudden). Open the inside main shutoff fully.
- Misadjusted or failing PRV. A PRV diaphragm rupture or spring fatigue can drop downstream pressure dramatically.
- Tuberculated galvanized supply (pre-1970 home, gradual decline over years). Repipe to PEX or copper.
- Pinched or undersized supply line (specific symptoms after recent renovation, or after a frost event on a buried service line).
- Hilltop elevation (always-low pressure in a hilltop home). May need a booster pump.
- Utility-side issue (sudden drop, neighbors confirm). Phone call to the utility.
Why this entry exists
This is the query-form sibling of the canonical Low water pressure entry. They cover the same content; this version optimizes for the question search “why is my water pressure low” while Low water pressure optimizes for the noun-form “low water pressure.”